Automatic Water Level Controller Switch 20A Tank Liquid Level Detection Sensor

$ 13.19

Availability: 85 in stock
  • Termination Type: Connector
  • Current Type: AC
  • Sensor Type: Electromechanical
  • Level Sensor Type: Multi-point Level Switch
  • Bundle Description: With Sensors
  • Country/Region of Manufacture: China
  • Condition: New
  • Brand: Relay
  • Custom Bundle: Yes

    Description

    Specification
    Product Name
    Water level controller
    Work voltage
    110V/60HZ
    Control distance
    500meters
    Work current
    20A
    Single-control UP pool (water storage) installation instructions shown in figure 1
    A(red)—Upper water level control point. When water level gets to A point,
    the probe touch water and controller can stop the pump by auto.
    B(blue)—Lower water level control point. When water level gets off B point,
    the probe out of reach water and controller can start the pump by auto.
    C(black)—Should be placed in bottom of pool as the common line.
    D(green) and E(yellow)are connected with C (black).
    Single-control DOWN pool(drain water)installation instructions shown in figure 2.
    E—Upper water level control point. When water level gets to E point,
    the probe touch water and controller can start the pump by auto.
    D—Lower water level control point. As liquid level gets off D point,
    the probe out of reach water and controller can stop the pump by auto.
    C—Should be placed in bottom of pool as the common line.
    A&B—disconnected
    Lack of water protection installation instructions shown in figure 3.
    C&D—Lower water level control points. When water level gets off this point,
    C or D probe out of reach water and controller can stop the pump by auto.
    E&C—short-connected;
    A&B—disconnected
    oint control UP and DOWN pool installation instructions shown in figure 4.
    A—Upper water level control point in UP pool. When water level gets to A point,the probe touch water and controller can stop the
    pump by auto.
    B—Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can
    start the pump by auto.
    C—Should be placed in bottom of UP and DOWN pools as the common line.
    D—Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop
    the pump by auto.
    E—Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start
    the pump by auto. Then pool starts to drain water. If not, E point disconnected
    Product Notes
    1. On power but no work:
    a. Check the red indicator is on or not. If not, make the connection is good enough;
    2. When water level is above or below probes but the pump does not start or stop by auto, Please check it like the following.
    a. Whether the probe is placed too high or low so that water level can reach or out of reach it;
    b. The connection of upper &lower line or probe is dislocation by error or short connected;
    c. To check the probe whether it is rust or not or the connection is good enough.
    d. C- Check the common line whether it is placed in the lowermost bottom of pool.
    Please see below Frequently Asked Questions
    Are these red, black, and blue sensors able to be in 190 degree hot water?
    This is stainless steel can bear that temperature but the wire can bear ,so it cant bear so much high temperature .
    What diameter, or measurement in inches, are the sensors? Are they all the same size?
    Yes ,they are the same size ,each sensor ,each sensor diameter is 14mm
    How long are the wires that are attached to them?
    We shipped for you with 2m ,The wire can do with 5m ,10m or 20m or more .
    How long you need ?
    What is the minimum distance between the sensors submerged in the water vertically?
    The sensor cant touch together .That will be ok
    What is used to anchor the wires so they do not move and stay in the correct place?
    You can install them all in the one hard pipe ,then put it in the tank ,that would be ok
    Does the controller send power directly to the pump at 120V?
    Yes ,it is better to join the contactor to enlong the life of the water level controller